Data Capability Name | VSS Data | TypeElements | VSS ||||||
---|---|---|---|---|---|---|---|---|
Data | ElementsType | Data Element Names(Per VSS) | Data Type | VSS Values | ||||
Provide On/Off State of HVAC system | ||||||||
boolean | IsAirConditioningActive | boolean | True/False | |||||
boolean | IsRecirculationActive | boolean | True/False | |||||
Provide On/Off State of Front Defroster | boolean | IsFrontDefrosterActive | boolean | True/False | ||||
Provide On/Off State of Rear Defroster | boolean | IsRearDefrosterActive | boolean | True/False | ||||
Provide Estimated Cabin Air Temperature | boolean | AmbientAirTemperature | float | degrees celsius | ||||
Structure | Station | Enumeration | - Row[1,4] - ["Driver","Passenger"] | |||||
Temperature | float | degrees Celsius | ||||||
Structure | Station | Enumeration | - Row[1,4] - ["Driver","Passenger"] | |||||
FanSpeed | uint8 | Percentage 0 to 100 0 = off, 100 = max | ||||||
Structure | Station | Enumeration | - Row[1,4] - ["Driver","Passenger"] | |||||
AirDistribution | Enumeration | ['UP', 'MIDDLE', 'DOWN'] | ||||||
Provide All Climate Settings per Zone (HVAC Station) | Array of Structure | Station | Enumeration | - Row[1,4] - ["Driver","Passenger"] | ||||
Temperature | float | degrees Celsius | ||||||
FanSpeed | uint8 | Percentage 0 to 100 0 = off, 100 = max | ||||||
AirDistribution | Enumeration | ['UP', 'MIDDLE', 'DOWN'] | ||||||
IsStationPresent (not in VSS) | boolean | True/False Is the Station present in THIS vehicle | ||||||
...